| Technical tests | Tested sample: Pipe diameter: Installation method: Liquid used in test: |
serv-Clip measuring clip 10... 42 mm direct installation Hydraulic oil Aero Shell Fluid 4 |
| High pressure test | Stress: Test pressure: |
static 2400 bar |
| Test result: |
No damages to the measuring clip could be detected. No leakages of the measuring clip could be detected. |
|
| Pulse pressure test | Stress: Test frequency: Impulse pressure: Cycles: |
dynamic 1 Hz 400 bar 1 Million |
| Test result: |
After completion of this load alteration test neither damages to nor leakages of the measuring clip could be detected. |
|
| Flow rate | The flow rate measured applies to the series SC-1-A-.....and its value remains the same for all serv-Clip sizes ranging from 10 .....42 mm, as all types are equipped with the same interior parts and needle diameters. |
|
| The flow rate was measured at an oil temperature of 25 °C. The testmedium is the hydraulic oil HLP 46, which means its viscosity is 46 mm2/s at 40 °C. The measurement was taken by means of a measuring hose of 1 metre lengths featuring a M 16 x 2 mm connection coupling |
![]() |
|